C1U-W-1200-12-Tx Series
AC/DC Front End Power Supply
OUTPUT CHARACTERISTICS
Parameter
Remote Sense
Conditions
Compensates for up to 0.12V of lead drop
with or without remote sense connected
Min.
Typ.
120
Max.
Units
mV
Ef?ciency
Output Rise Monotonicity
Startup Time
Transient Response
220Vac 90.6
Overshoot less than 10% for all outputs, no voltage negative between 10% t o 95% during ramp up
AC ramp up 1.5
PS_On activated 150
12V Ramp 1A/μs ±600
3.3Vsb Ramp 1A/μs ±165
5Vsb Ramp 1A/μs ±250
%
s
ms
mV
Current sharing accuracy (up to 3 in parallel)
Holdup Time
At 100% load
20
±10
%
ms
ENVIRONMENTAL CHARACTERISTICS
Parameter
Storage Temperature Range
Operating Temperature Range
Operating Humidity
Storage Humidity
Conditions
Non-condensing
Non-condensing
Min.
-40
0
10
5
Typ.
Max.
70
50
90
90
Units
°C
%
Shock
Sinusoidal Vibration
30G non operating
0.5G, 5 – 500 Hz
MTBF
Telcordia SR-332 @ 30°C
Demonstrated
200K
200K
hrs
hrs
CAN/CSA C22.2 No. 60950-1-07, 2nd Ed.
Safety Approvals
Input Fuse
Material Flammability
Switching Frequency
Weight
PROTECTION CHARACTERISTICS
UL 60950-1, 2nd Ed.
IEC 60950-1:2005 (2nd Edition); EN 60950-1:2006 +A11
Power Supply has internal 20A/250V fa st blow fuse on the AC line input
UL 94V-0
90KHz for Boost PFC Converter
165KHz for Main Output Converter
200KHz for Standby Output Converter
5.7 lbs (2.6kg)
Output
Voltage
12V
3.3Vsb
5Vsb
Parameter
Overtemperature
Overvoltage
Overcurrent
Overvoltage
Overcurrent
Overvoltage
Overcurrent
Conditions
Autorestart
Latching
Latching
Latching
Latching
Latching
Latching
Min.
55
13
107
3.57
6.5
5.6
5
Typ.
Max.
65
14
122
4.02
8
6
7
Units
°C
V
A
V
A
V
A
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Max.
Units
Insulation Safety Rating / Test Voltage
Isolation
Grounding
Input to Output - Reinforced 3000 Vrms
Input to Chassis - Basic 1500 Vrms
Output to Chassis
Output to Output
Main Output Return and Standby Output Return are connected internally. 100kΩ resistor parallel with 100nF
capacitor is connected between Return and power supply chassis. Main Output Return should be connected to
the System Chassis.
www.murata-ps.com/support
MPS_C1U-W-1200-12-Tx.A08 Page 2 of 5
相关PDF资料
C1U-W-1200-48-TB2C POWER SUPPLY 1200W AC/DC 48V
C23004 CAP PB SNAPFIT BLACK .590" DIA
C28PC,GY BOX 5.0X1.85X1.0 W/CLP GRY
C2PC,GY ENCLOSURE 1.25 X 1.90 X .50
C3900BA SWITCH TOGGLE SPST
C3900BE SWITCH TOGGLE SPST
C4V-821M SWITCH PUSH DPST-NO 8A 125V
C6000ALBB-1229W SWITCH ROCKER SPST 20A 277V
相关代理商/技术参数
C1U-W-1200-12-TC1C 功能描述:线性和开关式电源 1200W 12Vmain 3.3Vsb front-back airflow RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
C1U-W-1200-12-TC2C 功能描述:线性和开关式电源 1200W 12Vmain 3.3Vsb back-front airflow RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
C1U-W-1200-48-TA1C 功能描述:线性和开关式电源 1200W 48Vmain 5Vsb front-back airflow RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
C1U-W-1200-48-TA2C 功能描述:线性和开关式电源 1200W 48Vmain 5Vsb back-front airflow RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
C1U-W-1200-48-TB1C 功能描述:线性和开关式电源 1200W 48Vmain 12Vsb front-back airflow RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
C1U-W-1200-48-TB2C 功能描述:线性和开关式电源 1200W 48Vmain 12Vsb back-front airflow RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
C1U-W-1200-48-TC1C 功能描述:线性和开关式电源 1200W 48Vmain 3.3Vsb front-back airflow RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
C1U-W-1200-48-TC2C 功能描述:线性和开关式电源 1200W 48Vmain 3.3Vsb back-front airflow RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度: